Jinda Cable N2XRY Low Voltage Cable - Waterproof Connector

The N2XRY can be installed indoors, outdoors and underground, in pipes or in open environments where mechanical protection or high tensile forces are required during installation and operation. Because its conductors can withstand higher temperatures, it can be used in higher temperature environments.

$0.00
certificate:
TUV,CE
TUV,CE
CE
CE
  • Jinda Cable N2XRY Low Voltage Cable - Waterproof Connector
  • Jinda Cable N2XRY Low Voltage Cable - Waterproof Connector
  • Jinda Cable N2XRY Low Voltage Cable - Waterproof Connector
  • Jinda Cable N2XRY Low Voltage Cable - Waterproof Connector

Description

Application and description

The N2XRY can be installed indoors, outdoors and underground, in pipes or in open environments where
mechanical protection or high tensile forces are required during installation and operation. Because its
conductors can withstand higher temperatures, it can be used in higher temperature environments.
                                                                                                                                                                                 

Standards and certification

IEC 60502-1, VDE 0276-604, BS5467
                                                                                                                                                                                 

Cable structure

- Solid or multiple strands of bare copper conductor

- Follow DIN VDE 0295 cl.1/cl.2, BS 6360 cl.1/cl.2, IEC 60228 cl.1/cl.2

- Crosslinked polyethylene 2XI1 class, according to VDE 0276-604

- Color coding according to DIN VDE 0293(HD 308)

- PVC filling

- Galvanized steel wire/aluminum wire armouring

- PVC outer sheath DMV5, following HD 603.1
                                                                                                                                                                                 

Technical characteristics

- Operating voltage: 600/1000 V

- Test voltage: 3500 V

- Minimum bending radius: 15 x Ø

- Operating temperature: -5º C ~ +70º C

- Fixed installation temperature: -30 º C to +70º C

- Flame retardant: IEC 60332.1

- Insulation resistance: >20 MΩ x km
                                                                                                                                                                                 

Cable parameter

Core number x conductor Cross area # x mm²

Conductor type

Sheath thickness

Mm

Communication conductor

Cross area

mm²

Nominal outside diameter

Mm

Cable weight

kg/km

1x25

rm

0.9

1.8

16.6

503

1x35

rm

0.9

1.8

17.7

612

1x50

rm

1

1.8

19.5

783

1x70

rm

1.1

1.8

21.5

1014

1x95

rm

1.1

1.8

23.5

1280

1x120

rm

1.2

1.8

26.0

1575

1x150

rm

1.4

1.8

27.5

1872

1x185

rm

1.6

1.8

30.0

2294

1x240

rm

1.7

1.9

33.0

2923

1x300

rm

1.8

2.1

36.0

3509

1x400

rm

2

2

40.5

4534

1x500

rm

2.2

2.3

45.0

5691

1x630

rm

2.4

2.5

49.5

7267

1x800

rm

0.7

1.8

56.5

9271

2x1.5

re/rm

0.7

1.8

13.6

325

2x2.5

re/rm

0.7

1.8

14.5

379

2x4

re/rm

0.7

1.8

15.7

448

2x6

re/rm

0.7

1.8

16.8

530

2x10

rm

0.7

1.8

19.4

783

2x16

rm

0.7

1.8

22.0

982

2x25

rm

0.9

1.8

25.5

1447

2x35

rm

0.9

1.8

28.0

1765

2x50

rm

1

1.9

30.5

2106

2x70

rm

1.1

2

35.0

2765

2x95

rm

1.1

2..2

39.5

3746

2x120

rm

1.2

2.3

43.5

4465

2x150

rm

1.4

2.5

47.5

5303

2x185

rm

1.6

2.6

54.0

6890

2x240

rm

1.7

2.8

59.5

8463

2x300

rm

1.8

3.1

65.0

10151

3x1.5

re/rm

0.7

1.8

14.1

351

3x2.5

re/rm

0.7

1.8

15.1

415

3x4

re/rm

0.7

1.8

16.3

503

3x6

re/rm

0.7

1.8

17.5

603

3x10

rm

0.7

1.8

20.5

903

3x16

rm

0.7

1.8

23.0

1161

3x25

rm

0.9

1.8

27.0

1709

3x35

rm

0.9

1.8

29.5

2127

3x50

sm

1

1.9

31.5

2424

3x70

sm

1.1

1.9

36.5

3438

3x95

sm

1.1

2

40.0

4343

3x120

sm

1.2

2.2

43.5

5172

3x150

sm

1.4

2.3

49.5

6675

3x185

sm

1.6

2.5

54.0

7977

3x240

sm

1.7

2.6

60.0

9995

3x300

sm

1.8

2.8

65.0

11990

4x1.5

re/rm

0.7

1.8

14.9

395

4x2.5

re/rm

0.7

1.8

16.0

470

4x4

re/rm

0.7

1.8

17.4

575

4x6

re/rm

0.7

1.8

19.5

798

4x10

rm

0.7

1.8

22.0

1058

4x16

rm

0.7

1.8

25.5

1518

4x25

rm

0.9

1.8

29.0

2055

4x35

rm

0.9

1.9

32.0

2585

4x50

sm

1

2

35.5

3040

4x70

sm

1.1

2.1

41.0

4305

4x95

sm

1.1

2.2

45.0

5476

4x120

sm

1.2

2.4

51.5

7064

4x150

sm

1.4

2.5

57.5

8536

4x185

sm

1.6

2.7

61.5

10189

4x240

sm

1.7

2.8

68.0

12772

4x300

sm

1.8

3

73.5

15380

5x1.5

re/rm

0.7

1.8

15.8

441

5x2.5

re/rm

0.7

1.8

17.0

535

5x4

re/rm

0.7

1.8

19.3

768

5x6

re/rm

0.7

1.8

21.0

921

5x10

rm

0.7

1.8

23.5

1235

5x16

rm

0.7

1.8

27.0

1765

5x25

rm

0.9

1.8

31.5

2423

5x35

rm

0.9

1.9

34.5

3057

5x50

rm

1.1

2.2

40.0

4099

 


Product Advantages


Structural and Design Efficacy of the N2XRY Armored Cable

The N2XRY armored cable achieves superior mechanical protection through galvanized steel or aluminum wire armoring coupled with an optimized PVC outer sheath. This construction enhances resistance against abrasion, crushing forces, and environmental degradation. The waterproof low voltage cable design incorporates sealed connectors that mitigate water ingress risks, essential for underground power cable applications. Crosslinked polyethylene insulation guarantees stable electrical performance under thermal and mechanical stress. Its modular conductor size range and adherence to stringent standards like IEC 60502-1 and BS5467 provide design flexibility tailored to complex installation requirements encountered by low voltage cable suppliers.


Performance Excellence and Operational Benefits

This product by the N2XRY cable manufacturer offers high insulation resistance and flame retardant properties that ensure safety and longevity in demanding electrical installations. Its operating temperature parameters accommodate harsh climates and high-temperature industrial sites, enhancing system uptime. The cable’s flexibility and conductivity efficiency reduce installation time and operational energy losses. Waterproof connectors secure continuity in damp or underground environments, crucial for minimizing maintenance interventions. The combination of performance, durability, and compliance makes this low voltage cable supplier’s offering an optimal choice for engineering projects focusing on sustainability and regulatory adherence.



Use Scenarios


Underground Power Cable Applications in Urban Infrastructure

In urban development projects, the waterproof low voltage cable performs critically within underground power cable systems that require durable and reliable electrical transmission. The armored design protects against mechanical hazards like soil pressure and excavation activities, while waterproof connectors ensure moisture resistance under variable groundwater conditions. This cable integrates with municipal electrical distribution frameworks, supporting grid resilience and continuity. Its compliance with international testing standards reinforces safety assurance, facilitating straightforward inclusion in power distribution networks serving residential, commercial, and public facilities.


Outdoor Industrial Electrical Installations Requiring Armored Cable Durability

In outdoor industrial environments subject to heavy mechanical and weather-related challenges, N2XRY armored cable provides secure electrical connectivity. It is extensively deployed in factories, petrochemical plants, and transportation terminals where exposure to abrasion, temperature extremes, and water is routine. The low voltage cable supplier’s product withstands these conditions due to its rugged construction and waterproof connectors. Integration into complex industrial wiring systems is optimized by the cable’s standardized dimension ranges and conductor types, ensuring compatibility and maintaining uninterrupted electrical service vital for process efficiency and safety compliance in demanding settings.

 

FAQ 


What materials are used in the construction of the N2XRY cable?

Our N2XRY armored cable features solid or stranded bare copper conductors insulated with crosslinked polyethylene (XLPE). It is protected by either galvanized steel wire or aluminum wire armoring and encased in a PVC outer sheath, ensuring durability and high mechanical resistance in demanding environments.


Can I customize the conductor sizes for the Jinda Cable N2XRY Low Voltage Cable?

Yes, we offer conductor sizes ranging from 1x1.5 mm² up to 5x50 mm² depending on your project needs. This flexibility allows you to select the appropriate cable configuration while benefiting from reliable performance provided by Jinda as a trusted low voltage cable supplier.


Is the N2XRY cable suitable for underground power cable installations?

Absolutely. Our waterproof low voltage cable includes a specifically designed waterproof connector, making it ideal for underground installations. It withstands moisture and mechanical stress, providing stable and long-lasting power supply in harsh underground environments.


How do you ensure the safety and reliability of Jinda’s N2XRY cable in industrial applications?

We manufacture the N2XRY cable to meet stringent international standards such as IEC 60502-1, VDE 0276-604, and BS5467. It features flame retardant properties according to IEC 60332.1 and high insulation resistance, ensuring consistent and safe electrical performance in industrial and commercial projects.